LSM-B-SA1
Enables Force Measurement in X, Y and Z Directions. The Compact, Lightweight Strain Gage Based Design is Suitable for Model Experiments. (Patented)
10 to 500N
Notes : 1. Mx, My and Mz cannot be measured.
2. Arrows indicate directions of component force in plus
polarity acting to the B plane with the A plane fixed.
| Model |
Rated Capacity |
Natural Frequency
(Approx.)
|
Safe Moment
(Approx.)
|
Weight(Approx.) |
| Fx, Fy, Fz |
X,Y |
Z |
Mx,My,Mz |
| LSM-B-10NSA1 |
10N |
0.3kHz |
0.2kHz |
1.2N??m |
600g |
| LSM-B-20NSA1 |
20N |
0.4kHz |
0.3kHz |
2.4N??m |
| LSM-B-50NSA1 |
50N |
0.8kHz |
0.6kHz |
5.9N??m |
| LSM-B-100NSA1 |
100N |
1.3kHz |
0.9kHz |
9.8N??m |
| LSM-B-200NSA1 |
200N |
2.5kHz |
2.0kHz |
24N??m |
| LSM-B-500NSA1 |
500N |
2.2kHz |
1.8kHz |
59N??m |
1.6kg |
| Performance |
| Rated Capacity |
See table above |
| Nonlinearity |
Within ??0.5% RO |
| Hysteresis |
Within ??0.5% RO |
| Rated Output |
Approx. 0.5 mV/V (1000??m/m) |
| Environmental Characteristics |
| Safe Temperature Range |
0 to 80??C |
| Compensated Temperature Range |
0 to 70??C |
| Temperature Effect on Zero Balance |
Within??0.05% RO/??C |
| Temperature Effect on Output |
Within??0.05%/??C |
| Within??0.05%/??C |
| Safe Excitation Voltage |
10V AC or DC |
| Recommended Excitation Voltage |
1 to 5V AC or DC |
| Input Resistance |
240???5% |
| Output Resistance |
240???5% |
| Cable |
4-conductor (0.3 mm 2 ) chloroprene shielded cable,
4 mm diameter by 5 m long, with connector plug to the transducer side and bared to the amplifier side |
| (Shield wire is not connected to mainframe.) |
| Mechanical Properties |
| Mechanical Properties |
150% |
| Natural Frequency |
See table above |
| Weight |
See table above |
| Interference |
??3%RO |
| Safe Moment |
See table above |
* For the cable terminated with NDIS connector, suffix "-P" to the model number.