PGL-A
    
    
		    	
		        Compact, Lightweight, Highly Stable, and High Frequency Response
PGL-A series pressure transducers are suitable for pressure measurement in limited space. The semi-flush diaphragm at the top end ensures excellent response and dynamic characteristics. There are 2 types: Type A with removable cable and type B with integrated cable. (Patented)
 
        
    
					* TEDS-installed versions can be manufactured. Inquiries are welcome.			
    
    
    
    
    
        
    
					
	| Model | Rated Capacity | Natural Frequency (Approx.) | 
 
	| Connector Type | Cable Integrated Type | 
     | PGL-A-1MP-A | PGL-A-1MP-B | 1MPa | 48kHz | 
     | PGL-A-2MP-A | PGL-A-2MP-B | 2MPa | 74kHz | 
     | PGL-A-5MP-A | PGL-A-5MP-B | 5MPa | 122kHz | 
     | PGL-A-10MP-A | PGL-A-10MP-B | 10MPa | 149kHz | 
     | PGL-A-20MP-A | PGL-A-20MP-B | 20MPa | 210kHz | 
     | PGL-A-50MP-A | PGL-A-50MP-B | 50MPa | 294kHz | 
	| Performance | 
	| Rated Capacity | See table above | 
	| Nonlinearity | Within??0.5% RO (PGL-A-1 and 2MP-A/B) Within ??0.3% RO (PGL-A-3 to 50MP-A/B)
 | 
	| Hysteresis | Within??0.5% RO (PGL-A-1 and 2MP-A/B) Within ??0.2% RO (PGL-A-3 to 50MP-A/B)
 | 
	| Repeatability | 0.2% RO or less | 
	| Rated Output | 2 mV/V (4000??m/m) ??20% | 
	| (??30% with PGL-A-1 and 2MP-A/B) | 
	| Environmental Characteristics | 
	| Safe Temperature Range | -20 to 70??C | 
	| Compensated Temperature Range | -10 to 60??C | 
	| Temperature Effect on Zero Balance | Within??0.05% RO/??C (PGL-A-1 to 2MP-A/B) | 
	| Within??0.03% RO/??C (PGL-A-5 to 50MP-A/B) | 
	| Temperature Effect on Output | Within??0.03%/??C | 
	| Electrical Characteristics | 
	| Safe Excitation Voltage | 6V AC or DC | 
	| Recommended Excitation Voltage | 1 to 3V AC or DC | 
	| Input Resistance | 350???2% | 
	| Output Resistance | 350???2% | 
	| Cable | PGL-A-A: 4-conductor (0.18 mm 2  ) vinyl shielded cable, 4.6 mm diameter by 3 m long, terminated with connector plug
 | 
	| PGL-A-B: 4-conductor (0.08 mm 2  ) vinyl shielded cable, 3.2 mm diameter by 30 cm long, terminated with connector plug
 | 
	| (Shield wire is not connected to mainframe.) | 
	| Mechanical PropertiesConnector | 
	| Safe Overload Rating | 150% | 
	| Natural Frequency | See table above | 
	| Material | SUS 630 (liquid-contacting part) | 
	| Weight | Approx. 200 g (including cable) | 
	| Mounting Screw | G1/8, male | 
			 
    
        
    
					Gasket (mild copper) (SS-105 O-ring is also usable.)