LTP-S-S
Compact, Space-saving Design for Mounted In place of the Axis of Crane's Pulley
Mounted in place of the axis of crane's pulley, LTP-S-S series pin-type load cells enable measurement
of hanging loads.
Such the feature ensures easy installation and handling.
Since strain gages are used as the load detector, each load cell in this series is compact, lightweight and economically priced.
?? Specially designed for installation to pin connection
Model |
Rated Capacity |
LTP-S-10KNS |
10kN |
LTP-S-20KNS |
20kN |
LTP-S-50KNS |
50kN |
LTP-S-100KNS |
100kN |
LTP-S-200KNS |
300kN |
LTP-S-500KNS |
500kN |
Performance |
Rated Capacity |
See table above |
Nonlinearity |
Within??1 to 2% RO (depends on user's specifications) |
Hysteresis |
Within??1 to 2% RO (depends on user's specifications) |
Rated Output |
Approx. 0.5 to 1 mV/V (1000 to 2000??m/m) |
Environmental Characteristics |
Safe Temperature Range |
-20 to 80??C |
Compensated Temperature Range |
-10 to 70??C |
Temperature Effect on Zero Balance |
Within??0.05% RO/??C |
Temperature Effect on Output |
Within??0.05%/??C |
Electrical Characteristics |
Safe Excitation Voltage |
115V AC or DC |
Recommended Excitation Voltage |
1 to 10V AC or DC |
Input Resistance |
700???3% |
Output Resistance |
700???3% |
Cable |
4-conductor chloroprene shielded cable (length is as required) |
Mechanical Properties |
Safe Overload Rating |
150% |